JH-1800Y Stackable electricSyringe Pump diesel engine fuel feed pump - JH-1800Y
Place of Origin: Jiangsu China (Mainland) | Brand Name: JHHAO | Model Number: JH-1800Y | Drug library & Event log: 1030 kind of drug and reference dose, 5000 event logs |
Accuracy: +/- 2% with correct calibration | Language: Multilingual optional | Applicable syringes: 5ml,10ml,20ml,30ml,50ml,60ml | With drug libraries: 10 categories of common drugs,1030 kinds in total |
Bolus Volume: Maximum of 25ml | KVO Rate: 1ml/h programmable | Dimension: 230mm*150mm*125mm | name: Stackable syringe pump |
export: Stackable syringe pump | Type: Syringe Pump |
Stackable electricSyringe Pump /boiler feed pump JH-1800Y
Features
1. Compatible with syringes from (2/3ml), 5ml,10ml,20ml,30ml,50ml,60ml.
2. Stackable to be the maximum 8 channels.
3. High accuracy +/-2% after correct calibrated.
4. Three work modes: Rate mode, Time mode and Weight mode.
5. Bolus / Purge, KVO function.
6. With drug libraries:10 categories of common drugs,1030 kinds in total.
7. History recorded, real time displayed.
8. 6 hours continuous work after fully charged.
Technical Specifications
PARAMETER | SPECIFICATION |
Drug library & Event log | 1030 kind of drug and reference dose, 5000 event logs |
Language | Multilingual optional |
Applicable syringes | 5ml,10ml,20ml,30ml,50ml,60ml of any standard |
Accuracy | +/- 2% with correct calibration |
Rate mode | 50ml(60ml):0.1ml/h-1800.0ml/h (0.1ml/h step) 20ml(30ml):0.1ml/h-800.0ml/h (0.1ml/h step) 10ml:0.1ml/h-400.0ml/h (0.1ml/h step) 5ml (2/3ml): 0.1~200ml/h (0.1ml/h step) (Programmable 0.01ml/h~9999.9ml/h) |
Time Mode | SOL. VOL:0.1-999.9ml (0.1ml step) TIME:1-1999min (1min step) |
Body Weight Mode: | Volume:0.1-999.9ml(0.1ml step) DRUG MASS:0.1-999.9mg 0.1mg step) DOSE:0.01-99.99ug/kg/min(0.01ug/kg/min step) WEIGHT:0.1-300kg(0.1kg the least step) |
Total Volume Range | 0.1-1999.9ml (0.1 ml step) |
Purge Rate | 50ml(60ml):1800.0ml/h, 20ml(30ml):800.0ml/h, 10ml:400.0ml/h, 5ml (2/3ml): 200ml/h Programmable and adjustable |
KVO Rate | 1ml/h programmable |
Occlusion pressure | Three level setting LOW, MEDIUM or HIGH |
Alarms | Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures. Three levels of alarm volume LOW, MEDIUM or HIGH |
Bolus Rate | 5ml: 10~200ml/h,10ml:10-300ml/h,20ml(30ml):10-600ml/h, 50ml(60ml):10-1200ml/h Programmable and adjustable |
Bolus Volume | Maximum of 25ml |
Interface | RS-232 (Reserved port) |
Power source | AC power supply: AC 100 to 240V( +/-10%),50/60Hz; Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh. 6 hours of continuous operation |
Accessories: | AC power line, Operational manual |
Protection Class | Class I, Type CF,IPX4 |
Dimension / Net weight | 230mm*150mm*125mm , 2.0kg |
Packaging Detail:standerd expert packing |